Material·Corcho·
Corcho

Amorim Cork Insulation

100% natural expanded cork boards (ICB) from Portugal, with no synthetic additives.

Carbon negative Website
Amorim Cork Insulation

Description

Amorim Cork Insulation S.A., part of the Portuguese group Corticeira Amorim, manufactures Expanded Insulation Corkboard panels. The product is obtained by expanding cork granulate using steam, with no additives: only natural, recyclable cork is used. This process generates a 100% natural material with high dimensional stability, virtually unlimited durability and very low embodied energy, and the carbon balance is negative thanks to the CO2 fixed by the cork oak forests and the renewable energy used. These boards provide thermal, acoustic and anti-vibration insulation in a single product, with high thermal inertia and a delay in heat transmission. They have a density of around 110 kg/m³ and an approximate thermal conductivity of 0.036 – 0.038 W/m·K. They come in thicknesses from 10 to 300 mm and are suitable for roofs, façades, floors and walls, both in ETICS systems and for internal insulation; the company holds environmental certifications and promotes sustainable management of cork oak forests.

Go to their website

Density

100kg/m³

Lambda (λ)

0.04W/m·K

Fire resistance

Euroclase E

Formats

Tableros expandidos ICB, espesores 10-200mm, dimensiones estándar 1000x500mm

BIM AvailableNot available
Properties / Uses

Aislamiento térmico y acústicoanti-vibraciónparedes exteriores/interiorescubiertassuelos radiantes.

GWP · A1–A3
-2040kg CO₂e/m²
Data source

EPD verificada (EPD Hub HUB-0281, EN 15804+A2; válida 13-02-2023→13-02-2028): unidad declarada 1 m³ de aglomerado de corcho expandido ICB (115 kg/m³). GWP-total A1–A3 = −2.040 kg CO₂eq/m³ (GWP-fósil +82,8). El total negativo se debe al carbono biogénico capturado aguas arriba (alcornocal), que se reemite en fin de vida. ⚠️ No usar el dato '4554 kg C' impreso en el documento como almacenamiento del producto: es inconsistente con 115 kg/m³ (≈57 kg C ≈211 kg CO₂). PDF: amorimcorkinsulation.com (EPD ICB 2023).

Reviews
Do you manufacture this material?

Claim your listing: add your EPD, stand out in the comparator and appear right where the technician chooses the material.

Upgrade your listing

Technical questions and answers

What is the carbon footprint (GWP) of Amorim Cork Insulation ?
Amorim Cork Insulation declares a GWP (A1–A3) of -2040 kg CO₂e/m³.
What is the thermal conductivity (λ) of Amorim Cork Insulation ?
The declared thermal conductivity of Amorim Cork Insulation is λ = 0.04.
What is the density of Amorim Cork Insulation ?
Amorim Cork Insulation has a declared density of 100.
What is the fire resistance of Amorim Cork Insulation ?
The declared fire performance of Amorim Cork Insulation is Euroclase E.
Does Amorim Cork Insulation have an Environmental Product Declaration (EPD)?
Yes. Amorim Cork Insulation has a verified EPD (EPD HUB-0281) under EN 15804+A2.
Is Amorim Cork Insulation a carbon-negative material?
Yes. The biogenic carbon stored in Amorim Cork Insulation exceeds its manufacturing emissions (A1–A3), according to its environmental documentation.

Values as declared by the manufacturer or its EPD. Always check the current EPD/technical sheet for project-critical calculations.