Material·Madera·
MaderaEstructura

Garnica

European poplar plywood board certified PEFC/FSC with EPD, manufactured in La Rioja.

Carbon negative Website
Garnica

Description

European leader in poplar plywood board, headquartered in Logroño with several plants in Spain and France. Garnica manufactures lightweight boards from poplar sourced from PEFC/FSC-certified European plantations, a short-cycle crop that fixes carbon in agricultural land and boosts the rural economy. Its Efficiency, Duraply (exterior) and Fireshield (fire-resistant) ranges are used in construction, interior design, doors and vehicles. All three have an Environmental Product Declaration registered with EPD International — for example, EPD-IES-0005371 (S-P-05371) for Efficiency Poplar, valid until December 2026 — which facilitates their contribution to LEED and BREEAM certifications.

Go to their website

BIM AvailableNot available

GWP · A1–A3
-535.8kg CO₂e/m²
CO₂ sequestered

750kg/m³

Carbon negative
Yes
EPD / DAP

View document
Data source

EPD verificada (Environdec EPD-IES-0005371:003 / S-P-05371, 'Poplar Plywood Efficiency'; válida hasta 26-12-2026): unidad 1 m³ de contrachapado de chopo. GWP A1–A3 = 214 kg CO₂eq/m³ (PCR 2012:01, biogénico declarado aparte); CO₂ biogénico almacenado = 750 kg CO₂/m³ (EN 16449, declarado en la propia EPD); balance calculado por la propia EPD: −535,75 kg CO₂eq/m³. Nota jul-2026: el campo GWP_kg_CO2_m3 guarda ese balance (−535,8) para comparar en la misma base que el resto de tableros/maderas de la web, cuyos valores son GWP-total EN 15804+A2 CON biogénico (Superpan −593, XLAM −675, Arboreal −743…). Antes guardaba +214 (solo fósil), lo que le colocaba injustamente como 'impacto muy alto' frente a pares medidos con otra base. Estrictamente es 'balance' bajo PCR 2012:01, no GWP-total +A2 — mantener esta nota. También Duraply (S-P-05372) y Fireshield (S-P-05373). environdec.com/library/epd5371.

Reviews
Do you manufacture this material?

Claim your listing: add your EPD, stand out in the comparator and appear right where the technician chooses the material.

Upgrade your listing

Technical questions and answers

What is the carbon footprint (GWP) of Garnica?
Garnica declares a GWP (A1–A3) of -535.8 kg CO₂e/m³.
Does Garnica have an Environmental Product Declaration (EPD)?
Yes. Garnica has a verified EPD.
Is Garnica a carbon-negative material?
Yes. The biogenic carbon stored in Garnica exceeds its manufacturing emissions (A1–A3), according to its environmental documentation.

Values as declared by the manufacturer or its EPD. Always check the current EPD/technical sheet for project-critical calculations.